The PHASIFY™ DeCOVID SARS-CoV-2 RT-qPCR Kit is a RT-qPCR kit for detecting SARS-CoV-2 from human respiratory specimens, including nasopharyngeal swabs, oropharyngeal swabs and sputum. Developed in collaboration with Prof. Leo Poon, one of the world's leading scientists in emerging viruses at a Hong Kong University, the PHASIFY™ DeCOVID kit is a multiplex RT-qPCR detecting two specific sequences in the ORF1b region of SARS-COV-2 in a single reaction together with human RNase P housekeeping gene as the internal control

PHASIFY™ DeCOVID Advantage

High Sensitivity: Detect as low as 10 viral copies / mL for swab samples
Multiplex Detection: Support high throughput multiple-target testing
Scalability: Support large-scale routine screening and testing
Short Run Time: Complete real-time PCR program in an hour

Product Details

Product Code Unit Size
3010100 100x reactions

Specifications

Features Specifications
Test Principle One-step reverse transcription real time PCR
Targets Orf1b and RdRP as viral target,
RNase P as human internal control
Specimen type Respiratory specimens including nasopharyngeal swab, oropharyngeal swab, and sputum
Input volume 10 µL
Detection instrument Real time PCR instrument
with FAM, VIC and TAMRA detection channels
Limit of detection 10 viral copies / mL
(when used with the PHASIFY™ VIRAL RNA Extraction Kit)
Apporopriate run time (per 60 preps) 2 hours
Shelf life 6 months
Intended use For qualitative detection of SARS-CoV-2 nucleic acid extracted from human respiratory clinical specimens
Processing Manual
Shipping Condition Cold storage (dry ice)
Storage condition -20ºC or below, avoid repeated freeze thaw cycles

Data / Performance

PHASIFY™ DeCOVID demonstrated superior performance in detecting ORF-1b targets when compared to BGI’s FDA EUA RT-PCR Kit. When PHASIFY™ DeCOVID is combined with our PHASIFY™ VIRAL RNA extraction kit, the limit of detection of SARS-CoV-2 is further improved to as low as 10 cp / mL

I. Reduced Ct value against industry leading brand (BGI)

Figure 1 - SARS-CoV-2 virus in swab was extracted in the concentrations of 200, 500, 1000 and 5000 cp / mL using Qiagen Viral Mini RNA extraction kit. The virus RNA was amplified and detected using the multiplex PHASIFY™ DeCOVID SARS-CoV-2 RT-qPCR Kit or BGI qPCR Kit respectively. LoD for PHASIFY™ DeCOVID and BGI is 200 cp / mL and 500 cp / mL in swab specimen respectively

Figure 1 - SARS-CoV-2 virus in swab was extracted in the concentrations of 200, 500, 1000 and 5000 cp / mL using Qiagen Viral Mini RNA extraction kit. The virus RNA was amplified and detected using the multiplex PHASIFY™ DeCOVID SARS-CoV-2 RT-qPCR Kit or BGI qPCR Kit respectively. LoD for PHASIFY™ DeCOVID and BGI is 200 cp / mL and 500 cp / mL in swab specimen respectively

II. Increased screening sensitivity with the use of PHASIFY™ VIRAL

Figure 2 - SARS-CoV-2 virus in swab was extracted in the concentrations of 10, 20, 50, 100 and 200 cp / mL using PHASIFY™ VIRAL RNA extraction kit. The virus RNA was amplified and detected using the multiplex PHASIFY™ DeCOVID SARS-CoV-2 RT-qPCR Kit. LoD is 10 cp /mL in oropharyngeal swab specimen.

Figure 2 - SARS-CoV-2 virus in swab was extracted in the concentrations of 10, 20, 50, 100 and 200 cp / mL using PHASIFY™ VIRAL RNA extraction kit. The virus RNA was amplified and detected using the multiplex PHASIFY™ DeCOVID SARS-CoV-2 RT-qPCR Kit. LoD is 10 cp /mL in oropharyngeal swab specimen.

Product Resources

User Manual
Instruction for Use
Product Catalogue
Safety Data Sheets (SDS) a. SDS Nuclease free water
b. SDS 2x Reaction Buffer
c. SDS Enzyme Mix
d. SDS Primer Probe Mix
e. SDS No Template Control
f. SDS Positive Template

Product Sales and Customer Services

Email : phasify@phasesci.com | Customer Service : Hong Kong +852 3892-7200 (9am - 6pm UTC+8)
US +1 (657) 233-5880 (9am - 6pm Pacific)
Technical Support : Hong Kong +852 9135-2170 (9am - 6pm UTC+8)
US +1 (657) 296-6106 (9am - 6pm Pacific)
Email : phasify@phasesci.com
Customer Service :
Hong Kong +852 3892-7200
(9am - 6pm UTC+8)
US +1 (657) 233-5880
(9am - 6pm Pacific)
Technical Support :
Hong Kong +852 9135-2170
(9am - 6pm UTC+8)
+1 (657) 296-6106
(9am - 6pm Pacific)